Abstract

A rapid method was developed to efficiently measure 210Po in urine samples in an emergency situation. Polonium-210 in small urine samples (10mL) was spontaneously deposited on a stainless steel disc in 1M HCl at room temperature for 4h in a polyethylene bottle. The metallic disc was then counted for 4h by alpha spectrometry. The developed method allowed the preparation of large sample batch in a short time. The method meets the requirements for an emergency bioassay procedure.

Full Text
Published version (Free)