Abstract

For small size, low cost, and wide power range, the constant current (CC) control scheme suitable for both discontinuous conduction mode and continuous conduction mode (CCM) is prevalent in low and medium power applications. However long and short periods (LSP) emerge due to the inner control relationship of conventional flyback converter especially in CCM. An adaptive over current protection (OCP) control scheme is adopted to eliminate LSP. A threshold regulator and a calibrated protector are used to correct the OCP threshold dynamically in the proposed OCP circuit. To verify the feasibility and performance, the proposed scheme has been implemented in 0.18lm BCD process. The experimental results show that the LSP is eliminated and deviation of the CC is within ±1.04% under different input and load conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.