Abstract

The performance of a newly built omega type electrostatic analyzer designed to act as an in-line charge-state purification system for ions in the kiloelectronvolt energy range is reported. The analyzer consists of a set of four consecutive electrostatic 140° concentric cylindrical electrodes enclosed by Matsuda electrodes. This setup was recently tested and validated using O5+, Ar9+, and Xe20+ ion beams at an energy of 14 qkeV at the ARIBE facility. A resolving power of 10.5 and a transmission of 100% of the desired charge state are measured allowing a good purification of incoming ion beams with charge states up to 10+ and a fairly good purification for charge states at least up to 20+. In comparison with other in-line solutions such as the Wien filter, our system has the advantage of being purely electrostatic and therefore lacking common drawbacks as, for example, hysteresis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.