Abstract
Electronic scanning of a mosaic transducer array enables underwater sound pressure patterns to be reproduced on a cathode ray tube using intensity modulation. This report presents the design of a 16 element electronically scanned linear array mounted directly to the edge of a 10 cm by 15 cm printed circuit board. Microelectronic devices are used to confine all electronics to a 6 mm by 6mm cross section behind each array element. A large number of identical circuit boards such as this could be stacked to form a two-dimensional array suitable for acoustic image conversion or acoustical holography. A discussion of experimental results, size, and cost is given.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.