Abstract

An E-band (60-90 GHz) multi-channel Doppler backscattering (DBS) system with X-mode polarization has been installed on the Experimental Advanced Superconducting Tokamak (EAST), which can measure the turbulence at five different radial locations simultaneously. This system can launch 31 fixed microwave frequencies in the range of 60-90 GHz with a 1GHz interval into the plasma, and five probing signals are selected by employing a reference signal and multiple filters. During experiments, the frequency of the reference signal is tunable in the E-band, and the selected probing signals can be changed as needed without any other adjustments, which can be performed in one shot or between shots. Furthermore, the incident angle can be adjusted from -10° to 20°, and the wavenumber range is 4-25cm-1 with a wavenumber resolution of Δk/k ≤ 0.35. Ray tracing simulations are employed to calculate the scattering locations and the perpendicular wavenumber. In this article, the hardware design, ray tracing, and initial results obtained from the EAST plasma will be presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.