: For radiation treatment of patients with cervical cancer and a high risk for paraaortic lymph node involvement, an easy three-dimensional (3-D) conformal irradiation technique (partial half-beam [PHB]) for protection of organs at risk, especially of renal tissue, was developed. : In five consecutive female patients a computed tomography scan was performed. Dose-volume histograms of the renal tissue and other organs at risk were analyzed for PHB, three other 3-D conformal techniques, and an intensitymodulated radiotherapy (IMRT) technique. : The PHB technique reduced the renal volume and volumes of other organs at risk exposed to radiation doses when comparing all patients to the other 3-D conformal techniques. With use of the IMRT technique more renal tissue volume received very low radiation doses (</= 6.8 Gy) whereas the D(10)was lower than with the PHB technique. : In female patients with cervical cancer and high risk for paraaortic lymph node involvement, the use of the PHB technique is recommended to reduce renal radiation exposure, if no IMRT technique should be applied. The PHB technique is very easily and fast applicable.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.