Abstract

This paper presents an auxiliary passive circuit and control design for wireless power transfer (WPT) systems in DC microgrids to achieve optimal power transfer efficiency while maintain accurate output voltage regulation. An auxiliary inductance is added at the transmitter resonator to form a current sink to ensure zero voltage switching (ZVS) of the primary-side full-bridge inverter with even extremely light load conditions. Moreover, an adaptive proportional–integral (PI) controller is adopted to track the output voltage references by regulating the phase shift angle of the phase shift control for the full-bridge inverter. The coefficients of the adaptive PI controller are determined by the inductance of the auxiliary inductance. Both simulation and experimental results validated the effectiveness of the proposed circuit and control design in achieving optimal efficiency and output voltage regulation for WPT systems in DC microgrids with source and load variations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.