An automatic-slideback-type vacuum-tube voltmeter designed for measuring the peak voltage amplitude of recurrent video pulses is described. The slideback is made automatic through the use of a suitable amplifier and rectifier, the output of which is used to bias off a diode to the peak amplitude of the pulse to be measured. The effects of wave form and duty cycle of pulses on the accuracy of the device are considered, as well as modifications which can be used to decrease the inherent error due to diode capacitance. In addition, means of extending the voltage ranges and increasing the input impedance are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.