Abstract
An automated scheme to measure the open-circuit rotor time constant and set the slip gain of a field-oriented controller is presented. The test utilizes the pulse-width-modulated inverter of the drive itself and is conducted at zero speed so that the result can be used for automated calibration of the slip gain in the controller of an indirect field-oriented drive system. The accuracy of the test is verified by a simple measurement that checks for the existence of a linear relation between the input torque command and output torque at steady state.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.