Abstract

This paper develops a real-time automated fault detection interface and set-up for a multichannel bandwidth-limited system. This interface integrates both time domain reflectometry (TDR) and time domain transform (TDT) gating techniques which are combined with a signal analysis algorithm. Using a database of signal responses, the interface software can identify, locate and visualize positions of open, short and mismatched faults on a multiple-output system. In other words, the interface can simultaneously check the fault in the multichannel system with one step. Automated measurements were performed for a prototype of antenna system, which operates from 720 MHz to 960 MHz with one input channel and six output channels. Thus, it is possible that the testing solution can be replicated for similar multiple port systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.