Abstract
Cystic duct leak is an infrequent but potentially serious complication of laparoscopic cholecystectomy. The aims of this audit were to assess the efficacy of locking absorbable clips for closing the cystic duct and to compare the results with those for simple clips used previously. The records for all laparoscopic cholecystectomies performed in one hospital over a 5-year period were reviewed. The results were compared using Fisher's exact test. Of 518 laparoscopic cholecystectomies attempted, 24 were excluded. There was no difference in age or sex ratio between the two groups. Cystic duct leaks were identified either on endoscopic retrograde choloangio pancreatography or at laparotomy. No cystic duct leak occurred in any of the 344 locking clip cases, as compared with 3 leaks in the 146 (2%) simple clip cases (p < 0.03). Locking clips are a safe and effective method for cystic duct closure. They are associated with a reduced cystic duct leak rate, as compared with that for simple clips.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.