Abstract

This paper presents a direct photon-counting X-ray image detector with a <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">${\rm HgI}_{2}$</tex> </formula> photoconductor for high-quality medical imaging applications. The proposed sampling-based charge preamplifier with asynchronous self-reset enables a pixel to detect single X-ray photon energy with higher sensitivity and faster processing rate. The use of the correlated double sampling enabled by the sampling-based architecture also reduces flicker noise and contributes to the achievement of high pixel-to-pixel uniformity. Discrimination of the energy level of the detected X-rays is performed by the proposed compact in-pixel ADC with low power consumption. Three 15-bit counters in each pixel count up energy-discriminated photons for the reconstruction of multispectral X-ray images. A 128 <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">$\times$</tex> </formula> 128 X-ray image detector with a pixel size of <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex Notation="TeX">$60\times 60\ \mu{\rm m}^{2}$</tex></formula> is implemented and measured using a 0.13- <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">$\mu{\rm m}$</tex></formula> /0.35- <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">$\mu{\rm m}$</tex></formula> standard CMOS process. It discriminates 3 energy levels of photon energy with a gain of 107 <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">${\rm mV/ke}^{-}$</tex></formula> and a static power consumption of 4.6 <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">$\mu{\rm W/pixel}$</tex></formula> . The measured equivalent noise charge (ENC) and minimum detectable energy level of the detector pixel are 68 <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex Notation="TeX">${\rm e}^{-}\ {\rm rms}$</tex></formula> and 290 <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex Notation="TeX">${\rm e}^{-}$</tex></formula> , respectively. The measured maximum threshold dispersion in the pixel array is 164 <formula formulatype="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex Notation="TeX">${\rm e}^{-}\ {\rm rms}$</tex></formula> without any calibration. The functionality of our chip is also successfully demonstrated using real X-ray images.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.