Abstract

An important step in computer code development is the assessment of code capabilities through comparison of calculated results with experimental data A number of Creare countercurrent flow tests were simulated with the Transient Reactor Analysis Code (TRAC)-PD2 code to assess the emergency core coolant (ECC) lower plenum penetration and refill predictive capabilities. The tests examined in this study indicate a prediction of complete bypass and delivery at countercurrent steam flows where these phenomena occurred experimentally. Steam flows leading to partial delivery experimentally did not always lead to partial delivery in the calculations, however. A number of parameters can potentially effect TRAC refill calculations. Sensitivity studies indicate the TRAC results are most sensitive to droplet Weber number variations that affect interfacial shear and heat transfer rates. The condensation model also affects calculations with subcooled ECC liquid.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.