Abstract

Cardiovascular disease (CVD) patient outcomes can be improved by extracting and synthesizing as much useful information as possible from a limited number of available measurements. An important metric in assessing the pathological state of CVD patients is cardiac preload. Left ventricular preload can be estimated through the surrogate measurement of left ventricular end diastolic volume (LVEDV). However, cardiac volumes are difficult to measure, clinically. This study develops a 3 parameter model relating the location of the dicrotic notch in the aortic waveform to LVEDV. This model was constructed using data from porcine experiments (N = 5 pietrain pigs, weights 20-28kg). The median difference between the observed LVEDV and modelled LVEDV was 5.4%, with a 100% range of 3.0% to 15.1%. Model parameters varied between individuals as well as contractile states. The median correlation was ρ = 0.77, with a minimum of 0.58 and maximum of 0.95. This model could be used to estimate prseload from the commonly measured aortic pressure waveform.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.