Abstract

Experimental studies assessed the removal efficiency and fine-size distribution of CPM coupled with compositional analysis across air pollution control device systems (APCDs) at an ultra-low emission (ULE) power plant. The findings indicated total CPM emissions were reduced to a minimum of 0.418mg/m3 at the Wet Electrostatic Precipitator (WESP). The Wet Flue Gas Desulfurization (WFGD) showed the highest removal efficiency (98%) across all particle sizes, notably in the ultra-micron range. Selective Catalytic Reduction (SCR) demonstrated a mere 34% overall efficiency, with a negative removal rate in the ultra-fine particle range. The WESP effectively removed CPM only in sub-micron and ultra-micron sizes, but significantly increased water-soluble ions formation in ultra-fine spatially suspended CPM (CPMspa), leading to overall negative efficiency. Thus, the removal efficiency of the ultra-fine particle range was most affected among the three particle size ranges when the flue gas went through the APCDs. Major metal elements and water-soluble ions were more readily removed by APCDs due to their surface aggregation, while the removal of trace elements like Hg and Se was limited. Reducing SO42-/NH4+ formation in SCR, and optimizing WESP spray system operations based on flue gas components are essential steps in controlling CPM concentration in ULE power plants.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call