Abstract An assembly is described, in which electrochemical corrosion measurements can be carried out in aqueous environments up to 314 C (598 F) and 105.5 kg/cm2. Test specimen mounting and corrosive environment containment procedures are discussed. A techniqie for using a high pressure electrolyte bridge with an external reference electrode is described. The performance of the system is demonstrated by potentiostatic anodic, cathodic and linear polarization experiments carried out on AISI Type 304 steel in dilute chloride solutions at 289 C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.