Abstract
Abstract Heat transfer analysis of liquid-liquid Taylor flow in previous studies almost never shows the effect of slug length on heat transfer. The homogenous or single-phase analysis is often the only method available to deal with flow of multi components. In the present study a new approach is developed to model the segmented liquid-liquid Taylor flow as two separated systems and presenting heat transfer enhancement for each component. The effect of internal circulation and boundary layer renewal within the two fluid components is clearly observed. An experimental setup was assembled using open loop system at mini scale size in which liquid-liquid Taylor flow is heated under a constant wall temperature. Three silicone oils of 1, 3, and 5 cSt were segmented using distilled water at three volume fractions 0.25, 0.5 and 0.75. Finally, heat transfer data of the dimensionless mean wall heat flux shows good agreement with a predictive model proposed in an earlier work by the second author. The results show an impact of the fluid cell dimensions on the rate of heat transfer.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.