Abstract

Abstract Thin-layer chromatography was applied to radiochemical purity determination of sulfites (35SO2-3) and iodides (131)I−), in which the samples were chromatographed on silica gel sheet with acetone-water mixture as solvent. Prior to actual application, certain compounds of S and I contained as impurities in the (35SO2-3) and (131)I− were chromatographically separated. The Rf values were determined as function of the concentration of the acetone solvent and of the concentration of the species in the sample solutions. Acetone was found to be a very effective solvent, only requiring the ratio of mixture with water to be changed to yield the Rf value of any compound, thus permitting the selection of a wide variety of solvent composition according to the combination of compounds to be developed. The solvent composition also influenced the developing time, which furnished another criterion in selecting the solvent composition. The Rf value was also greatly affected by the concentration of the species to b...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.