Abstract
The design and construction of an apparatus for performing quantitative fretting fatigue experiments is described. The device allows accurate measurement and control of normal contact force, tangential contact force, relative displacement between contacting surfaces and bulk fretting loads, as well as measurement of average friction coefficients. Its design is simple, and includes interchangeable fretting contact pads, allowing the use of various pad geometries without major adjustment. The device incorporates many points of adjustment for alignment and compliance, making it a robust frame for a wide variety of fretting fatigue conditions involving different materials. The capabilities of this device are also verified by results of fretting fatigue experiments conducted on a 7075‐T6 aluminium alloy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Fatigue & Fracture of Engineering Materials & Structures
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.