Abstract

In this study, we highlighted differences in the standards used in performance tests of solar collectors. We analyzed testing results for different types of solar collectors to determine the effects of the collector area and mass flow rate, which were not necessarily consistent across all tests. Our analysis showed that the factor,F′ (τα), including collector efficiency factor (F′), could be correlated with the flow rate or area regardless of the collector type. Moreover, the collector loss coefficient (F′U L ) per flow rate or area for an evacuated collector was less that of a flat-plate collector; this was also correlated with the flow rate or area, regardless of the type of evacuated collector. As a result of this analysis, we propose a modified heat loss coefficient that includes the effects of all parameters that can be considered in a performance test and show that this coefficient could better describe the thermal characteristics of various types of solar collectors.