Abstract
Concrete-filled steel box columns are widely used as a major structural element in tall buildings as they provide efficient structural performance in resisting axial compression. Local buckling of steel plates is a common failure criteria when plate slenderness ratio is large in box sections. A method using an effective width principle is proposed in this paper to predict the behaviour and load carrying capacity of thin-walled steel tubes with concrete in-fill. The present investigation addresses columns pinned at their ends and subjected to biaxial loading. Columns tested by other researchers have been analysed using the proposed method and the predicted results are compared with the corresponding test results. The proposed model is also verified against Eurocode 4. The comparison shows that the method could predict the ultimate load with sufficient accuracy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.