Abstract
Since coaxial cables have excellent electromagnetic shielding characteristics, they are widely used as interconnecting cables for digital information equipment. However, since braided lines are used in the shield layer of most coaxial cables, if an RF current flows, a noise voltage (normal mode noise) is induced between the core wire and the braided wire by electromagnetic coupling. Electromagnetic noise is also radiated from the common mode current of the braided shield. It has been considered that ferrite core loading is effective for reduction of the electromagnetic noise, and such loading is frequently used. In this article, in order to study whether ferrite core loading is effective in reducing normal mode noise, the normal mode noise generated by the braided shield current is analyzed with respect to the core loading location. Next, a formula for the noise-reduction effect due to ferrite core loading is derived and its validity is demonstrated experimentally. © 1998 Scripta Technica, Electron Comm Jpn Pt 1, 82(2): 1–10, 1999
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Electronics and Communications in Japan (Part I: Communications)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.