Abstract

Previous work regarding low-rank matrix recovery has concentrated on the scenarios in which the matrix is noise-free and the measurements are corrupted by noise. However, in practical application, the matrix itself is usually perturbed by random noise preceding to measurement. This paper concisely investigates this scenario and evidences that, for most measurement schemes utilized in compressed sensing, the two models are equivalent with the central distinctness that the noise associated with double noise model is larger by a factor to [Formula: see text], where [Formula: see text] are the dimensions of the matrix and [Formula: see text] is the number of measurements. Additionally, this paper discusses the reconstruction of low-rank matrices in the setting, presents sufficient conditions based on the associating null space property to guarantee the robust recovery and obtains the number of measurements. Furthermore, for the non-Gaussian noise scenario, we further explore it and give the corresponding result. The simulation experiments conducted, on the one hand show effect of noise variance on recovery performance, on the other hand demonstrate the verifiability of the proposed model.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call