Abstract

An unfrozen water fraction prediction equation is proposed that compensates for both unfreezable water ( M b) and the equivalent molecular weight of solids ( MW s) during the food freezing process. The parameters ( M b and MW s ), when obtained from published unfrozen water content data, demonstrate that the proposed equation describes the data very well. When unfrozen water content data is not available, MW s can be obtained from the initial freezing point ( T f) of the food product, and M b can be obtained using calorimetric methods. The precision of MW s is shown to be very dependent on the precision of T f for a frozen food with medium (75%) to high (95%) moisture content. The precision of the input variables required in the proposed equations (temperature, M b, MW s, solids content) along with other physical parameters of the unfrozen food product (density, specific heat, and thermal conductivity) were investigated in an effort to determine the predictability of the frozen food density, apparent specific heat, enthalpy, thermal conductivity and unfrozen water content.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.