Abstract

The various harmonics in a power system are typically measured with a heterodyne receiver if we are using analog methods, or by a FFT (Fast Fourier Transform) when digital methods are being used. The harmonics can be analysed over a wide range of frequencies by means of these methods. However, since the circuit configurations that are needed can become very complicated, the equipment tends to be too expensive for practical use. This paper presents a novel harmonic meter using a PLL (Phase Locked Loop) circuit. By means of the phase feedback loop, a reference sinusoidal wave is locked on to the input signal along with the harmonics that we wish to measure, and hence the corresponding harmonic component in the input signal is easily detected. The effectiveness of the proposed harmonic meter is confirmed by experiment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.