Abstract
Abstract The cup methods are used extensively to determine the water vapor transport characteristics of building materials. The dry cup method and the wet cup method prescribe two standardized procedures for this purpose. The dry cup method gives the results as an average value of the property at a mean relative humidity of 25% and the wet cup at 75%. This information is inadequate for detailed hygrothermal analysis of building components. The complete dependence of water vapor permeability on relative humidity is required by most of the current computer models used for hygrothermal analysis. This paper presents an extension of the cup methods in which a series of dry cup and another series of wet cup measurements are suggested at varying relative-humidity levels outside the cup. Also, a detailed procedure for the data analyses to define the dependence of vapor permeability on relative humidity is presented. The methodology is applied successfully to three materials: perlite insulation board, calcium silicate insulation board, and plywood sheathing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.