Abstract

An alternative method for fingernail/electron paramagnetic resonance (EPR) dosimetry valid at low doses (0-3 Gy) is suggested in this paper. The method consisted of two steps. The first step involved dehydrating fingernail clippings to remove their water content by heating them at 70 °C for 72 h. As the water content in the fingernails decreased, the variability of the EPR signals improved. The second step involved measuring and fitting the EPR signals at successive microwave power levels. A newly derived value known as 'curvature', which was based on the conventional peak-to-peak amplitudes of the EPR signals, was applied for the dosimetry. This method could be used as an alternative method in cases of low-radiation exposure doses (<3 Gy) or where use of the conventional dosimetry method is not proper for a fingernail sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.