Abstract

The purpose of this study was to develop and test a simple, clinically practical alternative isovelocity surface (ISVS) model for calculating effective regurgitant orifice area (EROA) in mitral regurgitation (MR) when the regurgitant orifice is elongated, such as in functional MR. Clinical experience and 3-dimensional imaging suggest that the traditional hemispheric ISVS model used in the conventional proximal isovelocity surface area (PISA) calculation is invalid in certain MR cases and can cause erroneous EROA values. Our ISVS model consisted of 3 sections of equal radius (R): a cylindrical midsection of length (L) positioned between 2 hemispheroidal end sections. Total ISVS area (T(S)) is equal to 2πR(2) + πLR and EROA is equal to (V(N/)V(CW))T(S), where V(N) is the flow velocity crossing perpendicular to the ISVS, and V(CW) is the peak MR jet velocity by continuous-wave Doppler. This EROA was corrected for any obtuse angle, θ formed by tented leaflets, by multiplying T(S) by a planar factor, (θ/180) or a combination of this planar factor for the cylindrical midsection and the solid-angle factor, 1-cos(θ/2), for the 2 spheroidal end sections. In 24 cases of severe or 3+ functional MR, we calculated EROA using 3 traditional hemispheric surfaces and 3 alternative ISVS models that differed in the leaflet angle correction applied. Results were compared with continuity-based EROA using the standard mitral valve - aortic valve stroke volume method and with predictions based upon theoretical geometric considerations. The mean differences between continuity EROA and ISVS area-based EROA for no angle correction, planar correction, or combined angle correction were, respectively, 0.38, 0.32, and 0.28 cm(2) for the 3 spherical surface models and 0.17, 0.018, and -0.012 cm(2) for the 3 alternative 3-section ISVS models. The empiric EROA results with both the traditional spherical and alternative ISVS models agreed well with theoretical geometric predictions. The traditional spherical PISA model underestimates EROA in functional MR. For elongated MR orifices, an ISVS model that mirrors orifice shape yields more accurate EROA values. Correction to the ISVS area for obtuse leaflet angulation improves accuracy of EROA estimation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.