Abstract

In contemporary implant and prosthodontic practice, high levels of surgical and biologic success rates have been achieved. However, mechanical and technical complications continue to exist. Of these, one of the biggest challenges to the clinician is the conservative retrieval of fractured screw fragments from within the implants and/or abutments. While removal is desirable, the fragments cannot always be removed, and alternative solutions for the management of such clinical situations must be considered. This clinical report describes the replacement of 2 fractured, irretrievable, Locator abutment screws of a mandibular implant-retained overdenture with a cast dowel and laser welded Locator attachments. This alternative method was successful in managing broken abutment screw fragments while using the existing prosthesis and implants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.