Abstract

This study presents a deterministic constrained optimisation algorithm developed for using in a pressurized irrigation network. In irrigation networks —or water networks supplied by a head tank— utility managers can fully adapt the delivery times to suit their needs. The program provides a strategy for scheduling water delivery at a constant flow rate (opening and closing of hydrants, units, and subunits) to minimise energy consumption. This technique improves on earlier approaches by employing a deterministic method with little computing time. This method has been tested in the University of Alicante pressurized irrigation network, where decision-makers have identified the need to diminish the energy expenditure for watering University’s gardens.