The present paper describes a method for evaluating images of a bubbly flow in stirred aerated tanks which are typical when pulsed laser holography is applied as the measuring technique. Features of the brightness histograms of reconstructed bubble images are discussed. A procedure is presented to evaluate the bubble images taken from a reconstructed hologram in order to determine the center of gravity of the bubble image. Double pulsed holograms were taken to measure bubble velocities and diameters simultaneously. In this case, overlapping bubble images are sometimes observed in the reconstruction. This significantly impedes the evaluation of the characteristics of the bubbles. Thus, an algorithm is presented in this work to distinguish between single and overlapping bubble images and to separate the overlapping bubble image in a two-dimensional image for a bubbly flow at low void fraction recorded from double pulse holograms. This algorithm was confirmed to be effective if the bubble images are extracted from the entire image.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.