Abstract

An advanced technique for detecting incipient inter-laminar insulation failure in stator cores of large electric machines is proposed in this paper. The proposed scheme is an offline method based on low flux stator core excitation that employs a new probe. An iron-core probe is placed in the wedge depression area of the stator and scanned axially to detect the variation in the measured flux due to a fault. Two fault indicators that provide clear indication on fault severity and location are proposed in this paper. A 120-MW ac machine stator was tested under a number of intentionally inserted fault conditions using portable field equipment recently developed. The experimental results show that the fault existence, location, and severity can be determined reliably using the proposed scheme. It is also shown that the fault detection sensitivity and reliability, inspection speed, and user convenience are significantly enhanced.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.