Abstract
This paper presents an extended emulated digital retina model to compute two different retina channels in video real-time. The proposed emulated digital implementation of the two-channel retina model was compared to the previously developed single channel model from three different points of view: processing speed, number of physical cells and accuracy. A real-time test environment with camera input and display output is going to be set up to analyze the retina model implementation on emulated digital CNN (cellular neural/nonlinear network) model by using a 6M gate equivalent FPGA (field programmable gate array).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.