Abstract
The modified CPMG (Carr-Purcell-Meiboom-Gill) pulse sequence is a common sequence used for measuring the internal magnetic field gradient distribution of formation rocks, for which t0 (the duration of the first window) is a key acquisition parameter. In order to obtain the optimal t0, an adaptive method is proposed in this paper. By studying the factors influencing discriminant factor σ and its variation trend using T2-G forward numerical simulation, it is found that the optimal t0 corresponds to the maximum value of σ. Then combining the constraint condition of SNR (Signal Noise Ratio) of spin echo, an optimal t0 in modified CPMG pulse sequence is determined. This method can reduce the difficulties of operating T2-G experiments. Finally, the adaptive method is verified by the results of the T2-G experiments for four water-saturated sandstone samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.