Abstract

In acoustic decay measurement using the third-octave band pass filter, it is known that an inevitable experimental error is produced by “ringing” at the tail part of the impulse response of the third-octave band pass filter. This ringing gives rise to distortion of the decay curve. In order to reduce this error and to obtain an acceptable acoustic decay curve, it has been recommended that the product of the 3 dB bandwidth B of the third-octave band pass filter and the reverberation time T60 of the room under test be at least 16. For a listening room having short reverberation time and at the low-frequency band with narrow bandwidth, the decay curve cannot, therefore, be measured reliably by using the third-octave band pass filter. In this paper, the continuous wavelet transform (CWT) has been proposed to determine accurately the decay curve with a low value of BT60. The CWT decomposes an acoustic decay signal into time–frequency domain using the third-octave band wavelet filter bank. When the CWT is applied to the measurement of an acoustic decay curve, it is found that the requirement BT60>16 can be replaced by the replacementBT60 >4.