Abstract

This paper presents accurate and quantitative measurements of waveform parameters and eye pattern which is important as an evaluation parameter of digital transmission characteristics in the development of a wide-band automatic waveform analyzer from dc to 10 GHz. The measurements and-error of transfer characteristics by using FFT is also described. New techniques are adopted in averaging, calibrating, and compensating the time axis for the accurate measurements. Relevant software offers a method for quantitative measurement. The methods have made it possible to measure the waveform parameters which are about ten times more accurate than can be obtained through conventional oscilloscopes. In the quantitative evaluation of eye pattern, the measuring error has been improved from 10 down to 2 or 3 percent as compared with measurements by sight using a conventional oscilloscope. An equation which gives the approximate value of the error in the measurement of transfer function in the frequency domain from the time-domain pulse response is shown and confirmed to correspond with the actual case.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.