Abstract

An important aspect of electric power supply systems is their inherent response time to rapid changes in loading demands. This presentation reviews the experimental response of an Alkali Metal Thermal Electric Converter (AMTEC) system when switched from open circuit to stable, resistive loads. Our data show a nominal 35‐Watt AMTEC converter responded rapidly throughout the power curve. Response times from open circuit to delivering 90% of peak DC current were within 0.25 milliseconds to 0.85 milliseconds for a range of electrically resistive loads at several typical AMTEC operational temperatures. Such response times to load changes suggest that AMTEC may be suitable as a primary power supply, or backup power supply for critical space applications.