Abstract

We analyse the influence of real parameters of KMZ51 magnetic sensors on the accuracy and characteristic of AMR current measurement sensor. The device consists of a circular array of eight magnetic field sensors. The differences in sensitivity of individual AMRs, as well as bridge resistance, the resistance of compensation coil and compensation coil factor are discussed. Finally, we present the method how to compensate the mentioned errors by reading individual sensor outputs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.