Abstract

A broadband heterodyne reflectometer operating in the frequency range 75–110 GHz in extraordinary mode polarization is used at the W7-AS stellarator for both fast density profile determination and density fluctuation studies. The probing signal is amplitude modulated at a frequency 133 MHz using the envelope phase for profile evaluation and the carrier phase to determine the fluctuation information simultaneously. Separate Gaussian beam optics for final signal launch and detection permits a beam waist of about 2 cm at the reflecting layer in the plasma. Amplitude modulated detection is accomplished in the intermediate frequency part by synchronous detection after recovery of the carrier by narrow-band filtering. Voltage controlled solid state oscillators followed by active frequency multiplication allow to scan the full frequency band within less than 1 ms. For typical W7-AS operation the accessible density range is 1×1019 to 6×1019 m−3 for on axis magnetic field of 2.5 T and 4.5×1019 to 10×1019 m−3 for 1.25 T, respectively. The probed radial positions range between 0.2<r/a<1.1 depending on plasma conditions (a≊17 cm).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.