Abstract

AbstractA highly sensitive amperometric tyrosinase biosensor has been developed based on mesoporous composite films of carbon nanotube (CNT)–ZnO–Nafion composite film encapsulating tyrosinase on a glassy carbon electrode. Due to the mesoporous nature (diameter: 3.17 nm) of the composite film, the biosensor exhibits very fast response time of 2 s. The present biosensor shows an excellent sensitivity of 766 mA/M and a detection limit of 4.7×10−8 M (S/N=3) for phenol. The biosensor retains 88 % of its initial activity after 2 weeks of storage in 50 mM phosphate buffer at pH 7.0. The present biosensor exhibits good recovery for the spiked phenol in an industrial waste water sample.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.