Abstract
A hydrogen ion beam of 1.1 A, 35 keV was extracted for 1 hour from a modified duo PIGatron ion source. The extraction grids and the plasma source were cooled effectively and the ion source was operated stably. When the arc plasma current was controlled by the feedback signal from the accel current, the sufficiently stable ion beam was extracted from 2 msec to 1 hour after the ignition of arc plasma. The stabilities of the ion beam power and the divergence angle were both less than ± 0.5%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.