Abstract
Ammonium ion was colorized by means of a diazo coupling reaction with 2-phenylphenol, where the color development reaction was conducted within 3min by using boric acid as a catalyst. The resulting colored solution (0.5ml) was supplied by suction to a detecting tube consisting of a nonwoven fabric test strip (2mm wide, 1mm thick, 150mm long) impregnated with benzylcetyldimethylammonium chloride in a stripe pattern and enclosed in a heat-shrinkable tube. When the colored solution was supplied to the detecting tube, blue zebra-bands formed, and the ammonium concentration was determined by counting the number of zebra-bands. The detection range was 1-20mg-Nl(-1). Ammonium ion in actual domestic wastewater samples was successfully detected by means of this method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.