The modified Claus process is commonly used in oil refining and gas processing to recover sulfur and destroy contaminants formed in upstream processing. In oil refining, in addition to the typical modified Claus plant feed of H2S and CO2, NH3 is also often present. NH3 is a process contaminant and must be destroyed in the front-end furnace of the modified Claus plant, otherwise, it poses a risk of poisoning the catalyst beds and plugging off downstream equipment because of the formation of ammonium salts. In this paper, the pyrolysis and oxidation of NH3 was studied under Claus furnace temperatures and residence times. Experimental data was taken, and new reaction rate expressions were developed for NH3 pyrolysis and oxidation. The derived rate expressions are outlined as follows: the NH3 pyrolysis rate expression r = A exp(−Ea/RT)PNH31.25, where A is 0.00421 mol s-1 atm-1.25 cm-3 and Ea is 16.5 kcal mol-1, and the NH3 oxidation rate expression r = A exp(−Ea/RT)PNH3PO20.75, where A is 4430 mol s-1 atm-1....
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.