Abstract

This paper reports an ammonia cross-sensitivity elimination filter for SCR systems. Since NO X sensors are cross sensitive to NH 3 , a reading of NO X sensor could not be accurate. As the reading is inaccurate, the closed-loop SCR systems is unpredictable. The proposed filter can be applied to any kinds of NO X sensors and effectively remove the cross-sensitivity. Single gas and mixed exhaust gas tests are conducted. The results show the evident removal of NH 3 in both single gas and mixed gases experiments. The experiments show the filtering method can considerably improve the accuracy of NO X concentration measurement in Urea-SCR systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.