Amino acid analysis using direct electrochemical detection was compared with precolumn fluorescent derivatization using 6-aminoquinolyl- N-hydroxysuccinimidyl carbamate (AQC) for evaluation of the degree of covalent coupling of peptides to a carrier-protein complex derived from the bacteria Neisseria meningitidis. AQC derivatization was found to give superior sensitivity compared to electrochemical detection, with less interference from sample components such as carbohydrates or buffer salts. Hydrolysis time and temperature were optimized for maximal recoveries of the marker amino acid 6-aminohexanoic acid (epsilon-Ahx) and the unique amino acids S-dicarboxyethyl cysteine (SDCEC) and S-carboxymethyl homocysteine (SCHMC), which are generated upon the hydrolysis of the covalent linkage between the peptide and the carrier protein. Quantitation of these amino acids enabled the determination of the ratio of peptide to protein in the conjugate samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.