Abstract

Alternative to current liquid amine technologies for post-combustion CO2 capture, new technologies such as adsorbent-based processes are developed, wherein material lifetime and degradation is important. Herein a robust method to determine degradation rates in a laboratory setup is developed, which was validated with a continuous multi-staged fluidized bed pilot plant designed to capture 1 ton CO2 per day. An amine functionalized polystyrene adsorbent showed very good agreement between the experimental 1000-hour laboratory degradation rates and 2200 hours of degradation in a pilot plant. This validates how laboratory experiments can be extrapolated for sorbent screening and for scale-up. Resulting, the oxidative degradation in the desorber at high temperatures (120 °C) and low O2 concentrations (150 ppmv) is 3 times higher compared to the adsorber at low temperatures and high O2 (56 °C, 7 vol %). Laboratory degradation experiments can hence be used to further optimize process operations to limit degradation or screen for potential new adsorbents.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.