Abstract

Background: Surveillance metrics for catheter-associated urinary tract infections (CAUTIs) are subject to ongoing debate and refinement to best capture infectious catheter-related harm (ICRH) and noninfectious catheter-related harm (NCRH). Indwelling urinary catheters cause 5 times more NCRH than ICRH. The commonly used standardized infection ratio (SIR) does not fully capture NCRH nor the impact of prevention efforts in all settings. Alternatively, device utilization rates and ratios (DUR) do not reflect differences in other factors that may describe levels of device use. DUR lose comparability over time and across settings and can mask truly effective interventions by selecting for a higher risk group of catheterized patients. Experts now advocate use of the standardized utilization ratio (SUR). We sought to implement a multidimensional intervention to reduce exposure risk, CAUTI, and NCRH across a 5-hospital healthcare system, totaling 1,692 acute-care beds. Methods: The intervention comprised the following elements: (1) an interactive educational campaign comprising one-on-one engagements between infection preventionists and frontline providers, encouraging the use of female external urinary collection devices and male custom-fitted condom catheters, rewarding overall participation, device utilization, hand hygiene, and CAUTI rates; (2) educational emails to all staff from top executives; (3) increasing the urinalysis reflex to culture threshold from >5 to ≥10 WBCs; and (4) clinical decision support (CDS) for ordering urine cultures for patients with indwelling catheters and for encouraging Foley catheter alternatives and catheter removal. Monthly, quality department representatives discuss unit level DURs with managers, who then discuss patient-level device use at daily huddles with physicians and advanced practice providers. Significance was determined using the 2-tailed t test. The results are listed in Table 1. Discussion: One year after the intervention, use of device alternatives increased 5-fold, CDS-driven ordering predominated, and the SIR and SUR remained significantly decreased. These successes are especially notable because , a ventricular-assist device program was launched in the postintervention period. By the end of the study, the program became the second-busiest of its type in the United States, resulting in a group of patients at high risk of device use and infection in the postintervention period, but absent in the preintervention period. numerous reports of effective interventions for reducing CAUTI have been published, we found no large studies using the SUR as the main metric. The limitations of this study include the lack of a population SIR and data pertaining to catheter-related bacteriuria and antibiotic usage. However, this approach is easily customizable to any infection, device, and diagnostic test.Disclosures: NoneFunding: None

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call