Abstract

Standard diagnoses of SARS-CoV-2 infections are done by RNA extraction and real-time RT-PCR (rRT-PCR). However, the need for RNA extraction complicates testing due to increased processing time, high cost, and limited availability of commercial kits. Therefore, alternative methods for rRT-PCR detection of SARS-CoV-2 without RNA extraction were investigated. Nasopharyngeal and sputum samples were used to compare the sensitivity of three techniques: Trizol RNA extraction, thermal shock, and the direct use of samples with an RNase inhibitor. Direct, extraction-free use of primary samples plus the RNase inhibitor produced diagnostic values of 100 % sensitivity and specificity compared to standard protocols, and these findings were validated in a second, independent laboratory.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.