Abstract

BackgroundBreast density is a strong and potentially modifiable breast cancer risk factor. Almost everything we know about breast density has been derived from mammography, and therefore, very little is known about breast density in younger women aged <40. This study examines the acceptability and performance of two alternative breast density measures, Optical Breast Spectroscopy (OBS) and Dual X-ray Absorptiometry (DXA), in women aged 18–40.MethodsBreast tissue composition (percent water, collagen, and lipid content) was measured in 539 women aged 18–40 using OBS. For a subset of 169 women, breast density was also measured via DXA (percent fibroglandular dense volume (%FGV), absolute dense volume (FGV), and non-dense volume (NFGV)). Acceptability of the measurement procedures was assessed using an adapted validated questionnaire. Performance was assessed by examining the correlation and agreement between the measures and their associations with known determinants of mammographic breast density.ResultsOver 93% of participants deemed OBS and DXA to be acceptable. The correlation between OBS-%water + collagen and %FGV was 0.48. Age and BMI were inversely associated with OBS-%water + collagen and %FGV and positively associated with OBS-%lipid and NFGV.ConclusionsOBS and DXA provide acceptable and viable alternative methods to measure breast density in younger women aged 18–40 years.