Abstract

The study aim was to compare maze outcomes using microwave ablation or cryoablation in patients with mitral disease and atrial fibrillation (AF). Between 1999 and 2005, 340 patients underwent mitral valve surgery and concomitant maze procedure involving either microwave ablation (n=96, MW group) or cryoablation (n=244, Cryo group). Mean age at operation was 50.0±12.5 yr. Follow-up period was 46.1±28.2 months. The Cryo group showed a longer aortic clamping time than the MW group (P=0.005). There were no differences in operative mortality and morbidity rates. The unadjusted 5-yr AF free rate was 61.3±1.2% in the MW group and 79.9±3.2% in the Cryo group (P=0.089). After adjustment, the MW group only showed a tendency toward more frequent AF recurrence than the Cryo group (Hazard ration 1.66, 95% confidence interval 0.89 to 3.07). Multivariate analysis revealed that older patient age (P<0.001) and greater left atrial size (P<0.001) were independent risk factors for AF recurrence. Although the use of microwave ablation results in shorter aortic clamping time, it has a tendency toward more frequent late AF recurrence than with cryoablation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.